Please use this identifier to cite or link to this item: http://hdl.handle.net/2289/5841
Full metadata record
DC FieldValueLanguage
dc.contributor.authorVarma, Vijay-
dc.contributor.authorFujita, Ryuichi-
dc.contributor.authorChoudhary, Ashok-
dc.contributor.authorIyer, B.R.-
dc.date.accessioned2013-11-12T11:37:43Z-
dc.date.available2013-11-12T11:37:43Z-
dc.date.issued2013-07-15-
dc.identifier.citationPhysical Review D, 2013, Vol.88, p024038en
dc.identifier.issn1550-7998-
dc.identifier.issn1550-2368(Online)-
dc.identifier.urihttp://hdl.handle.net/2289/5841-
dc.descriptionOpen Accessen
dc.description.abstractExtreme mass ratio inspirals (EMRIs), the inspirals of compact objects into supermassive black holes, are important gravitational wave sources for the Laser Interferometer Space Antenna (LISA). We study the performance of various post-Newtonian (PN) template families relative to the waveforms that are high-precision numerical solutions of the Teukolsky equation in the context of EMRI parameter estimation with LISA. Expressions for the time-domain waveforms TaylorT1, TaylorT2, TaylorT3, TaylorT4 and TaylorEt are derived up to 22 PN order, i.e. O(v44) (v is the characteristic velocity of the binary) beyond the Newtonian term, for a test particle in a circular orbit around a Schwarzschild black hole. The phase difference between the above 22 PN waveform families and numerical waveforms are evaluated during two-year inspirals for two prototypical EMRI systems with mass ratios 10-4 and 10-5. We find that the dephases (in radians) for TaylorT1 and TaylorT2, respectively, are about 10-9 (10-2) and 10-9 (10-3) for mass ratio 10-4 (10-5). This suggests that using 22 PN TaylorT1 or TaylorT2 waveforms for parameter estimation of EMRIs will result in accuracies comparable to numerical waveform accuracy for most of the LISA parameter space. On the other hand, from the dephase results, we find that TaylorT3, TaylorT4 and TaylorEt fare relatively poorly as one approaches the last stable orbit. This implies that, as for comparable mass binaries using the 3.5 PN phase of waveforms, the 22 PN TaylorT3 and TaylorEt approximants do not perform well enough for the EMRIs. The reason underlying the poor performance of TaylorT3, TaylorT4 and TaylorEt relative to TaylorT1 and TaylorT2 is finally examined.en
dc.language.isoenen
dc.publisherAmerican Physical Societyen
dc.relation.urihttp://arxiv.org/abs/1304.5675en
dc.relation.urihttp://dx.doi.org/10.1103/PhysRevD.88.024038en
dc.rights2013 American Physical Societyen
dc.titleComparison of post-Newtonian templates for extreme mass ratio inspiralsen
dc.typeArticleen
Appears in Collections:Research Papers (TP)

Files in This Item:
File Description SizeFormat 
2013_PhysRevD_88_024038.pdfOpen Access348.27 kBAdobe PDFView/Open


Items in RRI Digital Repository are protected by copyright, with all rights reserved, unless otherwise indicated.